Agents Index

calc.engineer

Online

88 free engineering calculators: RF link budgets, LoRa/Meshtastic, PCB, solar, homelab. Keyless.

Visit publisherConnectJSON

What it can do: 80 tools

  • fsplCalculate free-space path loss (FSPL) in decibels using the ITU-R P.525 standard formula. Given a frequency in MHz and distance in kilometres, returns the expected signal attenuation in an ideal line-of-sight radio link
  • link_budgetCompute a full RF link budget from transmitter power, frequency, distance, and antenna gains. Calculates EIRP, free-space path loss (ITU-R P.525), received power at the receiver, and link margin relative to an optional r
  • dipoleCalculate physical dimensions of a dipole antenna for a given frequency. Returns half-wave or quarter-wave element length in metres, feet, and inches. A half-wave dipole is the most common resonant antenna with approxima
  • microstripCalculate PCB microstrip trace width for a target characteristic impedance using the Hammerstad-Jensen closed-form equations. Given target impedance (Z0), substrate dielectric constant (er), substrate height, and copper
  • dbm_convertConvert a power level in dBm to milliwatts, watts, dBW, and RMS voltage across a given impedance. dBm is the standard unit for RF power referenced to 1 milliwatt. This tool is essential when interfacing datasheets (which
  • noise_figure_cascadeCalculate the cascaded noise figure of a multi-stage receiver chain using the Friis formula. Each stage has a noise figure and gain in dB. The first stage dominates overall system noise, which is why low-noise amplifiers
  • vswrConvert between VSWR, return loss, and reflection coefficient — provide any one parameter and get all related impedance-mismatch metrics. Computes VSWR (voltage standing wave ratio), return loss in dB, reflection coeffic
  • attenuator_piDesign a Pi-topology resistive attenuator pad. Given a desired attenuation in dB and characteristic impedance (default 50 ohm), computes the three resistor values for a symmetrical Pi-pad network. The Pi attenuator uses
  • attenuator_teeDesign a Tee-topology resistive attenuator pad. Given a desired attenuation in dB and characteristic impedance (default 50 ohm), computes the three resistor values for a symmetrical T-pad network. The Tee attenuator uses
  • fresnel_zoneCalculate the Fresnel zone radius at the midpoint of a radio link. Given frequency in MHz, link distance in kilometres, and zone number (1-5), returns the Fresnel zone radius in metres and feet, plus the 60% clearance th
  • wavelength_freqConvert between radio frequency and wavelength. Provide either frequency in MHz or wavelength in metres, and get the full set of equivalent values: frequency in MHz and GHz, wavelength in metres, centimetres, millimetres
  • spice_templateGenerate a complete SPICE netlist from a parameterized template. Supports common circuit topologies: low-pass RC filter, voltage divider, common emitter amplifier. Returns a ready-to-simulate netlist string that can be p
  • spice_simulateRun a SPICE circuit simulation directly in the worker. Accepts a standard SPICE netlist and performs operating-point (.op), DC sweep (.dc), AC frequency sweep (.ac), or transient (.tran) analysis using a built-in modifie
  • lora_airtimeCalculates LoRa packet time-on-air using the Semtech AN1200.13 formula. Computes symbol duration, preamble time, payload symbol count, effective data rate, and the minimum transmission interval for 1% duty cycle complian
  • snr_marginComputes LoRa link SNR margin by comparing received power against the noise floor and the spreading-factor-dependent demodulation threshold from the Semtech SX1276 datasheet. Calculates receiver noise floor from thermal
  • channel_utilizationEstimates Meshtastic or LoRa mesh channel utilization percentage based on node count, message rate, and per-packet airtime. Determines how much of the shared radio channel is occupied and computes the maximum number of n
  • lora_range_estimateEstimates LoRa maximum communication range by computing the free-space path loss (FSPL) link budget and applying terrain-dependent correction factors. Calculates total link budget from transmit power, antenna gains, and
  • lora_sensitivityCalculates LoRa receiver sensitivity from spreading factor, bandwidth, and noise figure using the Semtech SX1276 datasheet SNR thresholds. Computes the noise floor from thermal noise density (-174 dBm/Hz), channel bandwi
  • duty_cycle_budgetCalculates LoRa duty cycle budget for EU868, US915, AS923, and AU915 regulatory regions. Computes maximum messages per hour, minimum transmission interval, and effective data rate under regional duty cycle constraints. E
  • meshtastic_rangeEstimates Meshtastic node communication range using real hardware profiles and firmware channel presets. Combines device-specific TX power and antenna gain (Heltec V3, RAK WisBlock, T-Beam, T-Beam Supreme, Station G2) wi
  • eirp_complianceChecks EIRP (Effective Isotropic Radiated Power) compliance against regional regulatory limits for LoRa and Meshtastic operation. Computes EIRP from transmit power, antenna gain, and cable loss, then compares against FCC
  • meshtastic_powerCalculates Meshtastic node power consumption and battery runtime using device-specific power profiles and firmware role-based duty cycling. Models sleep, RX, and TX current draw for Heltec V3, RAK WisBlock, T-Beam, T-Bea
  • lora_param_optimizerRecommends optimal LoRa spreading factor, bandwidth, and TX power based on target range, terrain, and optimization priority. Iterates through all SF (7-12) and BW (125/250/500 kHz) combinations, computing achievable rang
  • zfs_capacityCalculate usable ZFS pool capacity for any RAID level including stripe, mirror, raidz1, raidz2, and raidz3. Computes raw capacity, parity overhead, data disk count, usable terabytes after ZFS metadata overhead (checksums
  • zfs_ramCalculate recommended RAM and ARC sizing for a ZFS storage pool based on workload type, pool size, deduplication status, and L2ARC cache size. Computes minimum and recommended RAM in gigabytes, ARC target size, and dedup
  • tcp_throughputCalculate maximum TCP throughput using the Bandwidth-Delay Product (BDP) formula. Given link bandwidth and round-trip latency, computes the BDP (maximum in-flight data), achievable throughput with a given TCP window size
  • wireguard_mtuCalculate the optimal MTU for a WireGuard VPN tunnel interface with a detailed overhead breakdown. Accounts for WireGuard header (32 bytes), outer IP header (20 bytes IPv4 or 40 bytes IPv6), UDP header (8 bytes), and opt
  • subnet_calculatorCalculate IPv4 subnet details from CIDR notation. Parses a CIDR block (e.g. 192.168.1.0/24) and returns the network address, broadcast address, subnet mask, wildcard mask, first and last usable host addresses, total and
  • raid_iopsEstimate RAID array IOPS performance and latency for ZFS and traditional RAID configurations. Calculates maximum read IOPS, write IOPS (accounting for write penalty/amplification per RAID level), blended IOPS for a confi
  • power_costCalculate total power consumption, electricity cost, and circuit requirements for a homelab. Enter each device's wattage to get daily/monthly/yearly kWh and cost at your local electricity rate. Accounts for cooling overh
  • cooling_btuEstimate the cooling load (BTU/hr) for a homelab or server closet based on equipment wattage, room dimensions, insulation quality, and solar exposure. All electrical power converts to heat — this tool calculates equipmen
  • rack_capacityQuick rack space and weight sizing calculator for homelab and small data center racks. Enter your devices with their height in rack units, weight, and wattage to get total utilization, remaining free space, weight totals
  • network_bandwidthPlan and validate network link capacity for homelab workloads. Determine whether a 1G, 2.5G, 10G, or faster link can handle your concurrent streams (VMs, backups, media, iSCSI). Calculates effective bandwidth after TCP/I
  • thermal_enclosureEstimate steady-state thermal behaviour of a rectangular enclosure (server rack, electronics housing, equipment cabinet) using a lumped-parameter energy balance with natural-convection and radiation correlations, or forc
  • heatsink_cfdAnalyze a forced-convection fin-array heatsink using established channel-flow correlations (developing laminar Nusselt, fin efficiency tanh(mH)/mH, parallel-plate friction). Computes base-to-air thermal resistance, press
  • pcb_thermalEstimate PCB component temperatures by solving a thermal resistance network (thermal↔electrical analogy) with the built-in MNA solver. Each component gets a junction node (package θjb from a typical-datasheet table), a l
  • battery_lifeCalculates battery runtime and energy capacity given cell capacity in mAh, nominal voltage, and average current draw. Accounts for real-world discharge efficiency (Peukert-adjacent derating) to produce effective capacity
  • wire_gaugeDetermines the minimum AWG (American Wire Gauge) conductor size for a given current, voltage, one-way cable distance, and maximum allowable voltage drop percentage. Supports copper and aluminum conductors. Computes round
  • solar_sizingSizes an off-grid solar power system by calculating the number of panels and battery bank capacity required for a given daily energy consumption. Accounts for system losses (inverter, wiring, charge controller), battery
  • ups_runtimeEstimates UPS (Uninterruptible Power Supply) backup runtime from battery specifications and connected load. Takes VA rating, watt rating, load in watts, and battery configuration (count, voltage, amp-hours) to compute ef

…and 40 more.

Connect it

Claude Code
claude mcp add --transport http calc-engineer https://calc.engineer/mcp
Claude.ai / ChatGPT
Settings → Connectors → Add custom connector
URL: https://calc.engineer/mcp
Cursor (~/.cursor/mcp.json)
{
  "mcpServers": {
    "calc-engineer": {
      "url": "https://calc.engineer/mcp"
    }
  }
}
VS Code (.vscode/mcp.json)
{
  "servers": {
    "calc-engineer": {
      "type": "http",
      "url": "https://calc.engineer/mcp"
    }
  }
}

Questions

What does calc.engineer do?

88 free engineering calculators: RF link budgets, LoRa/Meshtastic, PCB, solar, homelab. Keyless. It exposes 80 tools to AI assistants.

What tools does calc.engineer provide?

80 tools, including fspl, link_budget, dipole, microstrip, dbm_convert, noise_figure_cascade, vswr, attenuator_pi, attenuator_tee, fresnel_zone, wavelength_freq, spice_template….

How do I connect calc.engineer to Claude, ChatGPT or Cursor?

Add the remote MCP endpoint https://calc.engineer/mcp as a custom connector or MCP server. Copy-paste setup is on this page.

Does calc.engineer require an account or API key?

No sign-in was needed to list its tools. Individual tools may still need an account or API key.

Is calc.engineer online?

As of 2026-11-19 our probe found it online. It answered 100% of our last 3 checks.

Who publishes calc.engineer?

calc.engineer. The official MCP Registry verified that the publisher controls this domain before accepting the listing.

Similar in Legal & Compliance