{"id":"ai.sparkquote/nec-calculators","slug":"ai-sparkquote-nec-calculators","title":"SparkQuote NEC calculators","description":"NEC 2023 electrical calculators: wire size, ampacity, voltage drop, conduit fill, box fill, load.","version":"1.0.1","publisher":{"kind":"domain","id":"sparkquote.ai","label":"sparkquote.ai","url":"https://sparkquote.ai"},"website":"https://sparkquote.ai/tools/mcp-server","repository":"","remotes":[{"type":"streamable-http","url":"https://sparkquote.ai/mcp"}],"packages":[],"published":"2026-10-14","updated":"2026-10-14","status":"online","auth":"","latency_ms":966,"checked":"2026-11-19","uptime":100,"checks":3,"tools":[{"name":"wire_size","title":"Wire size calculator","description":"Minimum conductor size for a circuit: NEC Table 310.16 ampacity at the termination temperature rating, the 240.4(D) small-conductor limits, voltage drop over the run, and the Table 250.122 equipment grounding conductor, increased in proportion under 250.122(B) when voltage drop upsizes the conductors.","read_only":true},{"name":"voltage_drop","title":"Voltage drop calculator","description":"Voltage drop for a given conductor size, current and one-way length, single- or three-phase, from NEC Chapter 9 Table 8 circular mils (VD = 2·K·I·L / CM, or √3 for three-phase).","read_only":true},{"name":"watts_to_amps","title":"Watts to amps calculator","description":"Current drawn by a load in watts at a voltage and power factor, single- or three-phase, plus the 125% continuous-load value.","read_only":true},{"name":"conduit_fill","title":"Conduit fill calculator","description":"Percent fill and maximum number of THHN/THWN-2 conductors of one size in EMT or PVC Schedule 40, from NEC Chapter 9 Tables 1, 4 and 5.","read_only":true},{"name":"box_fill","title":"Box fill calculator","description":"Minimum outlet box volume from NEC 314.16(B): conductor, device (2 each), clamp and grounding allowances times the Table 314.16(B) volume for the largest conductor.","read_only":true},{"name":"load_calculator","title":"Residential load calculator (NEC 220.82)","description":"Dwelling service load by the NEC 220.82 optional method: 3 VA/ft² lighting, small-appliance and laundry circuits, fixed appliances, demand factor, heating or cooling, and the minimum standard service size. Leave an appliance out to count it as 0 VA.","read_only":true},{"name":"ohms_law","title":"Ohm's law calculator","description":"Ohm's law and power: give exactly two of voltage, current, resistance and power; the other two are calculated.","read_only":true},{"name":"panel_schedule","title":"Panel schedule generator","description":"Lays circuits out on a 120/240 V single-phase or 208Y/120 V three-phase panel and totals the load per phase with the imbalance.","read_only":true},{"name":"bid_calculator","title":"Electrical bid calculator","description":"Electrical bid price from materials, markup, labor hours and rate, job costs, overhead and a target net margin (price = break-even / (1 − margin)).","read_only":true},{"name":"nec_ampacity","title":"NEC Table 310.16 ampacity lookup","description":"Allowable ampacity of one insulated conductor from NEC Table 310.16 (not more than three current-carrying conductors in a raceway or cable, 30°C ambient), before any adjustment or correction factors and before the 240.4(D) small-conductor limits.","read_only":true}],"server_info":{"name":"sparkquote","title":"SparkQuote NEC calculators","version":"1.0.0","websiteUrl":"https://sparkquote.ai/tools/mcp-server"},"category":"legal","tags":[],"kind":"remote","source":"registry","submitted":{},"first_party":true,"domain_rank":null,"score":100,"indexable":true,"first_seen":"2026-10-14","stars":0,"badges":[],"sponsor":null,"page":"https://agentsindex.org/agents/ai-sparkquote-nec-calculators/"}