{"id":"com.ampworth/ampworth","slug":"com-ampworth-ampworth","title":"Ampworth","description":"UK solar PV and heat pump calculators, with guides, on one server. Follows the MCS methods. No key.","version":"1.0.20261017","publisher":{"kind":"domain","id":"ampworth.com","label":"ampworth.com","url":"https://ampworth.com"},"website":"https://ampworth.com/developers","repository":"","remotes":[{"type":"streamable-http","url":"https://ampworth.com/mcp"}],"packages":[],"published":"2026-10-17","updated":"2026-10-17","status":"online","auth":"","latency_ms":1045,"checked":"2026-11-19","uptime":100,"checks":3,"tools":[{"name":"connection_route","title":"Network connection route","description":"Work out which ENA connection procedure a domestic installation of solar panels,\nbatteries or both falls under: connect first and notify the distribution network operator within 28\ndays, or apply and wait for approval before anything is connected.\n\nThe rules are the ENA's engineering recommendations, not MCS documents: EREC G98 for small\ninstallations, EREC G99 for everything larger, and EREC G100","read_only":true},{"name":"get_document","title":"Read one document in full","description":"Fetch the full text of one guide, article or set of questions by its slug, as Markdown, not\nHTML. Slugs come from search_documents or list_documents.\n\nThe answer carries the MCS documents the text draws on, and the ids of any calculators on this site\nthat do the arithmetic the text describes. Where the document is a set of questions, each question and\nanswer comes back separately.\n\nCite the MCS do","read_only":true},{"name":"heat_pump_noise","title":"Heat pump noise assessment","description":"Calculate the sound pressure level an air source heat pump produces at an assessment\nposition, and whether it meets the 37 dB(A) permitted development noise limit, using the method in\nMCS 020.\n\nThe formula is Lp = Lw + 10 log(Q / 4.pi.r^2) - Ab.\n\nLw is the A-weighted sound POWER level of the unit from its product fiche, energy label or the MCS\nproduct database. This is not the sound pressure level","read_only":true},{"name":"heat_pump_running_cost","title":"Heat pump running cost","description":"Compare what a household spends heating on its current fuel with what the same heat\nwould cost from a heat pump.\n\nThe heat demand is worked out from the household's own metered fuel use, not from a model,\nbecause a year of bills describes a particular house far better than any estimate of it. Supply the\nannual fuel use in the fuel's own unit (kWh for gas and electricity, litres for oil and LPG, ki","read_only":true},{"name":"heat_pump_size","title":"What size heat pump do I need?","description":"Estimate the heat pump a UK house needs, and what it would cost to run against the\nfuel it burns now.\n\nIMPORTANT: MIS 3005-D requires a heat pump to be sized from a room-by-room heat loss calculation to\nBS EN 12831, and nothing here replaces that. Say so whenever you report a result from this, and point\nthe user at the room-by-room calculation. What the figure is for is checking whether a size som","read_only":true},{"name":"hot_water_cylinder","title":"Hot water demand and cylinder size","description":"Work out the daily hot water demand of a dwelling and the size of cylinder a heat\npump needs, using the formula in MIS 3005-D 3.5.2 and the BS 6700 guidance reproduced in MGD 007.\n\nThe demand is 45 litres a day for each of N, where N is the greater of the number of bedrooms plus one\nand the number of people actually living there. For a new build, where occupancy is unknown, the\nbedroom count is us","read_only":true},{"name":"list_calculators","title":"List the calculators and their reference data","description":"Lists every calculator on this server, with the standard behind it and whether it is the whole-system sizing calculator or one of the single-method ones, plus the reference data a caller needs to build a valid request: the compass directions and their orientations, the shading descriptions, the twenty-five solar postcode zones, the eight heat pump design locations with their design temperatures, t","read_only":true},{"name":"list_documents","title":"List what the documents cover","description":"Lists every document, optionally filtered by kind ('guide', 'article' or 'faq'), by category, or, for guides, by the reader they are written for. Guides are shelved by perspective: 'considering', 'buying', 'selling', 'installing' and 'learning'. The first four are plain language and name no standards; 'learning' carries the methods and the citations. Match the perspective to the person asking. Use","read_only":true},{"name":"radiator_flow_temperature","title":"Radiator flow temperature","description":"Work out the flow temperature a heat pump must produce to heat a room through a\ngiven radiator, and the resulting MCS Heat Emitter Guide star rating, following section 4 of MGD 007.\n\nThis is the calculation that decides whether a heat pump will be cheap or expensive to run. A heat\npump's efficiency falls as the water temperature rises, by roughly two to three per cent per degree,\nand the temperatu","read_only":true},{"name":"room_heat_loss","title":"Room heat loss","description":"Calculate the design heat loss of a single room in watts, following BS EN 12831 as\nMIS 3005-D applies it. This is the figure a heat pump is sized from and the figure the radiator in\nthat room must be able to deliver.\n\nBS EN 12831 is a room-by-room method. Run this once for each heated room and add the results; sizing\na heat pump from floor area alone is what produces the oversized installations th","read_only":true},{"name":"search_documents","title":"Search the documents","description":"Search the guides, articles and questions for material on a UK home energy subject.\n\nUse this first, before answering from memory, whenever a question concerns UK heat pump or solar PV\npractice: how a system is sized, what a standard requires, what a quotation should contain, what\nneeds planning permission, or what a figure on a quotation means. The material here is written\nagainst the published M","read_only":true},{"name":"solar_pv_output","title":"Solar PV annual output","description":"Estimate the annual AC electricity output of a UK solar photovoltaic system, in kWh,\nusing the standard estimation method that MIS 3002 requires every MCS certified installer to use.\n\nThe method is: annual output = kWp x Kk x SF, where Kk is read from the MCS irradiance dataset for\nthe site's postcode zone, roof pitch and orientation, and SF is a shade factor between 0 and 1.\n\nSupply the postcode ","read_only":true},{"name":"solar_pv_self_consumption","title":"Solar PV self-consumption","description":"Estimate what proportion of a domestic solar PV system's annual output is consumed in\nthe house and what proportion is exported, using the lookup tables in MGD 003.\n\nThe tables are not a model. They come from half-hourly monitoring of real British households by\nLoughborough University, with battery behaviour modelled on top, so they carry the real shape of\ndomestic demand: a peak before the sun is","read_only":true},{"name":"solar_pv_shading","title":"Solar PV shade factor","description":"Convert a completed MCS sunpath shading assessment into a shade factor, using the\nprocedure in MGD 005.\n\nThe MCS sunpath chart is divided into 84 segments, each worth one per cent of the year's useful\nirradiance. An assessor stands at the middle of where the array will go, plots what blocks the\nhorizon onto the chart, and counts the segments covered. This tool takes that count and returns\n1 minus ","read_only":true},{"name":"solar_pv_system_size","title":"What size solar system do I need?","description":"Work out the solar PV system a UK home needs: the capacity in kWp, the number of\npanels, the battery to go with it, and what it would do to the electricity bill.\n\nThis runs the MCS arithmetic backwards. The other solar calculators here each answer one question\nabout a system somebody has already specified. This one starts from what a household uses and\narrives at the system that covers it, which i","read_only":true}],"server_info":{"name":"ampworth","title":"UK home energy calculators and documents, following the MCS standards","description":"Every Ampworth tool on one server: the solar and heat pump sizing calculators, the nine single-method calculators, and search and reading of the guides, articles and questions. The same tools are also served separately at /mcp/calculators and /mcp/documents.","version":"1.0.0","websiteUrl":"https://ampworth.com"},"category":"productivity","tags":["travel","web-search"],"kind":"remote","source":"registry","submitted":{},"first_party":true,"domain_rank":null,"score":100,"indexable":true,"first_seen":"2026-10-17","stars":0,"badges":[],"sponsor":null,"page":"https://agentsindex.org/agents/com-ampworth-ampworth/"}