{"id":"com.datasheetvend/datasheet-contracts","slug":"com-datasheetvend-datasheet-contracts","title":"DatasheetVend","description":"Turn datasheets into source-backed JSON contracts, pinout matrices, and KiCad CAD for AI agents.","version":"1.1.0","publisher":{"kind":"domain","id":"datasheetvend.com","label":"datasheetvend.com","url":"https://datasheetvend.com"},"website":"https://datasheetvend.com/for-agents","repository":"https://github.com/FelixNovaNexus/datasheet-vend","remotes":[{"type":"streamable-http","url":"https://datasheetvend.com/api/mcp"}],"packages":[],"published":"2026-10-27","updated":"2026-10-27","status":"online","auth":"","latency_ms":2851,"checked":"2026-11-19","uptime":100,"checks":3,"tools":[{"name":"datasheetvend_extract_document_map","title":"Map a datasheet (deterministic index)","description":"Build the Document Map of a datasheet PDF: a deterministic, machine-readable index of WHERE the topics live (pinout, package, mechanical, electrical, timing, thermal, absolute_max, registers, cautions …) and WHAT each page physically looks like (table / prose / vector_drawing / raster_image / blank / honest unknown), including a per-page geometry census (vector paths, ruling lines, raster coverage","read_only":true},{"name":"datasheetvend_read_document_map_instructions","title":"Document Map usage instructions","description":"Return the versioned usage instructions for Document Map consumers: the binding rule (SHA-256 + physical pages), field semantics, the dominant_form action table, and the measured routing discipline. Call once per session before working with maps from datasheetvend_extract_document_map; do not call repeatedly — the text is static per contract version.","read_only":true},{"name":"datasheetvend_inspect_document_page","title":"Inspect one mapped page (Tier-2 detail)","description":"Tier-2 detail for ONE page of an already-mapped datasheet: the full measured anatomy (text metrics, MuPDF geometry census, structural geometry signals), the page's own headings and first lines, and which modules claim the page. Use it AFTER datasheetvend_extract_document_map, when the Tier-1 index says a page matters and its one-line summary is not enough. Pass the document.sha256 from the map (se","read_only":true},{"name":"datasheetvend_search_document","title":"Search the source datasheet of an extraction","description":"Find where the source datasheet behind an extraction job says something: every text token containing the term, with its page and its box on the page in PDF points. Use it to check an extracted value against the document, or to find the page to read with datasheetvend_read_document_page. Counts are honest: total_hits with hits_returned, a per-page cap of 20 stated with dropped_hits, and fetch_trunc","read_only":true},{"name":"datasheetvend_read_document_page","title":"Read one page of an extraction's source datasheet","description":"Read one page of the source datasheet behind an extraction job as positioned text tokens (text and box in PDF points), in reading windows of at most 1500 tokens (token_offset / next_token_offset). Carries the page's census: text_token_count, vector_path_count, raster_image_count. textless=true means no positioned text (a drawing, a scan, or an old map), not a blank page; payload_elided=true means ","read_only":true},{"name":"datasheetvend_locate_evidence","title":"Locate an extraction's values on its source pages","description":"For every extracted value of an extraction job (one module, or all of them), find the exact words on the source datasheet page the extraction cites and return their box: x, y, width, height normalized 0-1 to the page (origin top-left) plus bounds_pt in PDF points. Each value gets exactly one status: located (its own words boxed, inside or beside the cited snippet), located_value_only (its words oc","read_only":true},{"name":"datasheetvend_list_module_packets","title":"List every module's packet coverage for an extraction job","description":"For each extraction module (pinout, absolute_max, thermal, logic_levels, power_battery, timing, part_decoder, register_map, peripheral_matrix, analog_intelligence, passive_bom, pin_cautions), what its packet holds of the job's parsed datasheet: status (routed, routed_partial, nothing_routed: a statement about routing, never about the part), the target package it is scoped to, notes (what the packe","read_only":true},{"name":"datasheetvend_get_module_packet","title":"Read one module's packet of an extraction job's datasheet","description":"One extraction module's packet: the blocks of the parsed datasheet that module needs, in reading order, each with its reasons (which heading, caption or content tag put it there, from which block), table cells and drawings as a crop box plus the exact words inside them, each with its box. The header (sections with their block ids, coverage) comes whole; blocks come in windows (block_offset / next_","read_only":true},{"name":"datasheetvend_list_document_sections","title":"List the sections of an extraction job's datasheet","description":"The section tree of the job's parsed datasheet: each section's id (its heading block), heading text, level and printed number, page and box of the heading, parent section, heading path, block and subsection counts and page span. Paged (offset / next_offset, at most 300); filter by max_level and page range. Deterministic: reads the job's stored parse (parsed_document_v1), calls no model and extract","read_only":true},{"name":"datasheetvend_read_document_section","title":"Read one section of an extraction job's datasheet","description":"One section's blocks in reading order (text, table cells, drawing crop boxes), each with its block id, page and box, in windows (block_offset / next_block_offset, at most 80 blocks or about 40000 characters). include_subsections adds the blocks of every section below it. Long texts and large tables are cut and say so; datasheetvend_read_document_block returns one block whole. Deterministic: reads ","read_only":true},{"name":"datasheetvend_neighbor_document_section","title":"Step to the next or previous section of an extraction job's datasheet","description":"The section after (direction next) or before (direction previous) the given one in reading order. scope any: the adjacent heading of any level; same_or_higher_level: skip deeper subsections. at_end=true when there is none. Deterministic: reads the job's stored parse (parsed_document_v1), calls no model and extracts nothing. Costs no credits. Needs a DatasheetVend API key; readable jobs are your ow","read_only":true},{"name":"datasheetvend_read_document_block","title":"Read one block of an extraction job's datasheet","description":"One parsed block whole: type, page, box, text and markdown (each up to 20000 characters), heading, caption, links, its section and heading path, table cells with their boxes (up to 2000) or a drawing's crop box and the exact words inside it with their boxes (up to 400), and how many cross-references it prints or receives. Deterministic: reads the job's stored parse (parsed_document_v1), calls no m","read_only":true},{"name":"datasheetvend_read_document_table_rows","title":"Read a table's rows from an extraction job's datasheet","description":"One parsed table's printed rows in print order (row_index 0 = top row; two rows with the same values stay two rows), each with its line text as printed, its cells (cell_id, text, box, row_span, col_span) and the cells spanning down into it (covered_by). A spanning cell is listed once, in its first row. Also the table's caption and its continuation onto other pages. Paged (row_offset / next_row_off","read_only":true},{"name":"datasheetvend_follow_document_reference","title":"Follow a block's cross-references in an extraction job's datasheet","description":"The cross-references a block prints ('see Table 9', 'Figure 6', 'on page 41'), each resolved: resolution block (the referenced table, figure or heading, with its id, page, box and a text preview), page (only its page is known) or unresolved; the references elsewhere in the document that point at this block; and for a table, its continuation (the table it continues on an earlier page, the tables co","read_only":true},{"name":"datasheetvend_search_document_blocks","title":"Search the parsed blocks of an extraction job's datasheet","description":"Case-insensitive text search over the parsed blocks' text and table cells: each hit gives the block id, page, type, box and a snippet; a table hit also gives the cell's id, row, column and box. Scope it to a section (section_id, or heading_text) and to the job's target package; filter by pages and block types; paged (offset / next_offset, at most 100 hits). Unlike datasheetvend_search_document (ra","read_only":true},{"name":"datasheetvend_check_design_value","title":"Check a design value against a datasheet's rules","description":"Check one design value against every rule DatasheetVend extracted from a datasheet (its pin-cautions rulebook): for example a 4.7 kΩ pull-up, a 100 nF decoupling capacitor or a 3.6 V supply. Returns pass, fail or needs_review per rule that applies, with the rule's datasheet source, and a summary that counts EVERY rule, including the ones that could not be compared, so 0 failures never hides 'nothi","read_only":true},{"name":"datasheetvend_crosscheck_netlist","title":"Audit a KiCad netlist against extracted datasheets","description":"Audit a KiCad netlist against the datasheets your account has extracted with DatasheetVend. Compares symbol names with the datasheet, checks every pin exists, supply and ground pins sit on rails of the right kind and voltage, NC pins are left open, pin functions agree across each net, and pull-ups and the electrical rules that have data to run. `verdict` says how many pins were really compared and","read_only":true},{"name":"datasheetvend_match_kicad_footprint","title":"Match chips to official KiCad footprints","description":"Find the official KiCad library footprint for chips from their package numbers. An id comes back only when pin count, pitch and body size agree on source evidence and exactly one official footprint fits; otherwise the status is 'ambiguous' (with the candidates and what separates them) or 'unresolved' (with the reason), and footprint_id is null, because a wrong footprint on a board is worse than no","read_only":true},{"name":"datasheetvend_check_parts_compatibility","title":"Check whether chips work together (draft wiring)","description":"Will these chips work together? Ask before you have a netlist. Reads ONLY the extraction jobs you pass (2-12, from your account; repeats are removed, and two runs of one part are one part), drafts a starting wiring from pin names the way the DatasheetVend Workbench does (one elected microcontroller wired to each device over I2C or SPI), runs the electrical rules on it and answers per pair. The ans","read_only":true},{"name":"datasheetvend_resolve_part_number","title":"Resolve a part number against a datasheet's own legend","description":"Resolve a full ordering code against a datasheet your account already extracted with the part_decoder module: the document's own part-number legend and ordering table, as that run read them. Returns the status verbatim, each parsed position with its meaning, page and snippet, any unexplained characters, the ordering-table match and the merged package and temperature facts. The meaning is the docum","read_only":true},{"name":"datasheetvend_estimate_power_budget","title":"Estimate supply current and battery life","description":"Estimate a system's supply current and battery life (not thermal power dissipation) from parts your account extracted: total active current (mA), total standby current (uA), a breakdown per part and battery life on six standard batteries, as the DatasheetVend Workbench POWER tab computes it. Reads ONLY the jobs you pass: include each part's power_battery run, and its pinout run (it sets the role a","read_only":true},{"name":"datasheetvend_explain_warnings","title":"Explain an extraction's warnings","description":"Report the warnings an extraction raised, grouped and ranked by DatasheetVend's own classifier (the grouper the result page's warnings panel uses). Use it before trusting an extraction. Report BOTH counts: issues (distinct problems) and findings (occurrences). Use the severity given (critical, review, info); an info group or one marked internal is a pipeline note, not a problem with the part, and ","read_only":true},{"name":"datasheetvend_diagnose_extraction","title":"Diagnose what happened to an extraction","description":"Explain what happened to an extraction, module by module, from recorded state. Keep the outcomes apart: never_requested (not asked for, not a failure), nothing_found (ran; the datasheet does not document it), needs_review, still_running and failed (a recorded error). When failureReason is present, lead with whose problem it is (our_infrastructure means re-running is worth it). Quote the recorded r","read_only":true},{"name":"datasheetvend_compare_extractions","title":"Compare one module across extractions","description":"Compare the SAME module across 2-4 of your extraction jobs in one aligned table, instead of reading each job. Rows align on key_field (default: the pin or register identifier) and compare value_field (default: the name); pass `keys` for specific pins or registers. Parts are never merged: values are positional per job, and a key missing from one part is null there. A job whose outputs expired, whos","read_only":true},{"name":"datasheetvend_search_my_extractions","title":"Search your extractions","description":"Find your own (non-archived) extraction jobs by condition: filename words, a module that produced output, jobs with warnings, or jobs waiting on a decision. Returns job ids, status, warning counts and which modules hold output, never module data: pass an id to the other tools (datasheetvend_explain_warnings, datasheetvend_compare_extractions, datasheetvend_search_document) or read GET /api/v1/jobs","read_only":true},{"name":"datasheetvend_assess_datasheet","title":"Assess a datasheet before extracting it","description":"Judge whether a datasheet PDF is likely to extract well BEFORE you spend credits on it. Pass the public https URL of the PDF (datasheetvend_search_component_library returns one as datasheet_pdf_url). It reads up to 25 pages and checks structure deterministically: the text layer (scanned or image-only PDFs extract less reliably), page count, which standard datasheet sections are present (sectionsFo","read_only":true},{"name":"datasheetvend_get_part_pack","title":"Buy a part pack","description":"Buy one part pack: a component's frozen module outputs (pinout, footprint, limits, timing and the others the manifest lists) as one JSON envelope. Price: 3 module credits with a DatasheetVend API key, charged once per account (the same pack again is free), or $2.00 per call with a Stripe machine payment (no account, so each call pays). The pack is found before anything is charged: a missing pack, ","read_only":false},{"name":"datasheetvend_extract_pinout","title":"Extract datasheet pinout","description":"Extract a component's pin/pad table from a datasheet PDF as verifiable, provenance-tracked evidence — not raw PDF text to re-interpret. Returns a PinoutEvidence document (contract pinout_evidence_v1): the canonical pins and special pads with names/types/functions. It also RESOLVES THE PACKAGE from the terminals — `package.family`, `package.variant` (e.g. SOT-223, TQFP-32) and `package.pin_count` —","read_only":true},{"name":"datasheetvend_extract_thermal_limits","title":"Extract thermal resistance and operating limits","description":"Extract thermal characteristics: junction-to-ambient (θJA) and junction-to-case (θJC) thermal resistance, power dissipation limits, and operating/junction/storage temperature ranges — with the datasheet page where one was recorded. A thermal resistance value the table reader could not prove complete or correctly placed carries review_required: true and a review_reason saying what to check in the P","read_only":true},{"name":"datasheetvend_extract_absolute_max","title":"Extract absolute maximum ratings","description":"Extract the Absolute Maximum Ratings: never-exceed supply/pin voltages, max currents, and storage temperatures. Use extract_logic_levels for the OPERATING supply range, not these stress limits. canonical_output.value_checks labels each delivered min, max and unit by the check that reached it: verified means OCR of the printed page agreed; flagged values list both readings. No label claims a value ","read_only":true},{"name":"datasheetvend_extract_logic_levels","title":"Extract DC logic levels and operating conditions","description":"Extract DC electrical characteristics: VIH/VIL/VOH/VOL thresholds, Schmitt hysteresis, AND the VCC/VDD operating supply voltage range. Use this for supply-range questions; extract_absolute_max gives never-exceed limits. Runs DatasheetVend Fast Extraction: a page scout routes targeted model reads and the module's own deterministic readers, then the same normalization and completion checks as a dash","read_only":true},{"name":"datasheetvend_extract_timing_characteristics","title":"Extract AC timing characteristics","description":"Extract AC timing: setup/hold (tSU, tH), propagation delays, maximum clock frequencies (fMAX), rise/fall times, and bus timing. Runs DatasheetVend Fast Extraction: a page scout routes targeted model reads and the module's own deterministic readers, then the same normalization and completion checks as a dashboard job finish the result, usually in seconds; `engine` names the engine on every result. ","read_only":true},{"name":"datasheetvend_extract_register_map","title":"Extract hardware register map","description":"Extract the register map: memory addresses, reset values, access permissions (RO/RW/W1C), and per-bit field definitions. canonical_output.value_checks labels each value by the check that reached it: verified means an outside source (OCR of the printed page, the vendor's register file) agreed; flagged values list both readings. No label claims a value is true of the chip. canonical_output.svd_cover","read_only":true},{"name":"datasheetvend_extract_package_dimensions","title":"Extract package dimensions and land geometry","description":"Extract mechanical package outline dimensions (D, E, A, A1, e, L, b) and a nominal land geometry estimate in the spirit of IPC-7351B (review-level, not a manufacturer land pattern). For the package variant/pin count from the pin table, prefer extract_pinout. Runs DatasheetVend Fast Extraction: a page scout routes targeted model reads and the module's own deterministic readers, then the same normal","read_only":true},{"name":"datasheetvend_decode_part_number","title":"Decode manufacturer ordering part numbers","description":"Decode the ordering nomenclature: per-position suffix meanings (temp grade, package, speed, packaging) and, where the datasheet's ordering information supports it, the enumerated orderable_part_numbers list — the direct answer to 'which/how many orderable part numbers'. Codes the document's ordering legend lists that the decode lacks come back as deterministic_harvest_only_rules, each with its sou","read_only":true},{"name":"datasheetvend_extract_peripheral_matrix","title":"Extract on-chip peripheral matrix","description":"Extract the on-chip peripheral inventory, one row per instance, in 13 classes: serial/communication (UART/USART, SPI, I2C, CAN, USB, Ethernet, SDIO, I2S/SAI), analog blocks (ADC, DAC, comparator, op-amp, voltage reference, temperature sensor), timers and watchdogs, DMA, security/math accelerators (crypto, RNG, CRC), external memory interfaces (FMC/FSMC/EMC, memory-mapped QSPI), display/camera/touc","read_only":true},{"name":"datasheetvend_extract_analog_specs","title":"Extract analog domain specifications (ADC/DAC, Op-Amps, VREF)","description":"Extract analog conversion and signal-conditioning specs: ADC/DAC resolution, sampling rates (MSPS/kSPS), channel counts, input-voltage ranges, static non-linearity (INL/DNL), dynamic specs (ENOB, SINAD, SNR, SFDR, THD), operational amplifiers (GBW, slew rate, rail-to-rail, CMRR/PSRR), internal voltage references (nominal voltage, tempco ppm/°C), and operating supply/temp envelopes, plus comparator","read_only":true},{"name":"datasheetvend_extract_power_domains","title":"Extract power domains and consumption","description":"Extract power supply domains (VDD/VDDA/VBAT), low-power/sleep modes and their consumption, and battery-backup configuration. Runs DatasheetVend Fast Extraction: a page scout routes targeted model reads and the module's own deterministic readers, then the same normalization and completion checks as a dashboard job finish the result, usually in seconds; `engine` names the engine on every result. If ","read_only":true},{"name":"datasheetvend_extract_passive_bom","title":"Extract passive support BOM","description":"Extract the recommended passive support components: decoupling/bypass capacitors, crystal load caps, and pull-up/down resistors, with their values and the pins they connect to. Runs DatasheetVend Fast Extraction: a page scout routes targeted model reads and the module's own deterministic readers, then the same normalization and completion checks as a dashboard job finish the result, usually in sec","read_only":true},{"name":"datasheetvend_extract_pin_cautions","title":"Extract pin cautions and design rules","description":"Extract hardware design cautions: bootstrap/mode-strapping requirements, 5V-tolerant vs 3.3V-only pin boundaries, reset/debug pin precautions (NRST filtering, SWD pull-ups), oscillator/crystal PCB guardrails, analog/power-domain isolation (VDDA/VBAT), and unconnected/reserved-pin handling. Each caution row includes source_page, source_text_snippet, and verified source_evidence bounding box coordin","read_only":true},{"name":"datasheetvend_extract_kicad_footprint","title":"Extract KiCad PCB footprint (.kicad_mod)","description":"Write a KiCad PCB footprint (.kicad_mod) from a datasheet's package mechanical drawing: pad geometry, pitch, thermal tabs and courtyard, using the datasheet's own recommended land pattern when it prints one, otherwise simplified IPC-7351B fillet math. Emitted files are loaded with kicad-cli (sym/fp upgrade) where it is installed, which is a file-format check, not a DRC or ERC. Only bundle_status \"","read_only":true},{"name":"datasheetvend_extract_kicad_symbol","title":"Extract KiCad schematic symbol (.kicad_sym)","description":"Write a KiCad schematic symbol library (.kicad_sym) with logical pin groupings (Power, Ground, Reset, Clocks, GPIO, Analog, Bus interfaces) from a datasheet's pinout. Symbol layout is generated from the pin functions the pinout module resolved; there is no IEEE/IEC symbol-drawing standard applied. The emitted file is loaded with kicad-cli (sym upgrade) where it is installed, a file-format check, n","read_only":true},{"name":"datasheetvend_extract_kicad_bundle","title":"Extract complete KiCad CAD bundle","description":"Generate a KiCad footprint (.kicad_mod) and schematic symbol (.kicad_sym) from a datasheet in one call. Both files are loaded with kicad-cli where it is installed (a file-format check, not a DRC/ERC) and passed through the same deterministic copper, courtyard, pin-1 and pad-placement checks the dashboard uses. bundle_status \"completed\" means both files were independently proven against this docume","read_only":true},{"name":"datasheetvend_extract_altium_bundle","title":"Parse an Altium Designer ASCII footprint export","description":"Parse an Altium Designer ASCII footprint export (a text file — NOT a binary .PcbLib/.SchLib) and extract the footprint name, per-pad copper geometry (designator, name, coordinates, size, shape), layer map, and this module's own review/audit verdict. This reads an EXISTING Altium file; it does not build one from a datasheet PDF (for that, see the Altium Assist output pack on a completed extraction ","read_only":true},{"name":"datasheetvend_search_component_library","title":"Search the component library","description":"Search DatasheetVend's component library: parts from dozens of manufacturers whose manufacturer datasheet DatasheetVend stores. Search by part number, vendor, package, architecture or application words (for example 'STM32 QFN', 'ESP32', 'BLE wearable', 'Cortex-M4'), optionally filtered by vendor, package family, category, pin range or Verified Pack. Each result gives the part page, the stored data","read_only":true},{"name":"datasheetvend_calculate_land_pattern","title":"Estimate a land pattern (IPC-7351-style, generic)","description":"Estimate a land pattern from package numbers: a generic IPC-7351-style pad width, pad length and courtyard for a perimeter package (QFN/DFN/SON leadless, or QFP/SOIC/SSOP/TSSOP/SOP gull-wing). This is a nominal estimate, NOT IPC-7351B's tolerance-stacked tables, NOT IPC-certified and NOT the datasheet's recommended land pattern: use the datasheet's own drawing when it prints one. It gives one pad ","read_only":true},{"name":"datasheetvend_get_part_pack_manifest","title":"See a part's shelved packs","description":"See what DatasheetVend has shelved for a part BEFORE buying: each package variant's part pack, with the modules it holds and the ones it does not (module_count_available of module_count_total), its warnings, the source jobs and the manufacturer datasheet link. A missing part answers 'no shelved pack'. Free, no API key, no model call. Buy a pack with datasheetvend_get_part_pack.","read_only":true},{"name":"datasheetvend_list_hardware_modules","title":"List the hardware intelligence modules","description":"List all available hardware extraction modules supported by DatasheetVend (KiCad footprints/symbols, Universal Pinout, Thermal Limits, Absolute Maximum Ratings, Timing Characteristics, Logic Levels, Register Maps, Decoupling Passive BOM, Part Number Decoders, etc.).","read_only":true},{"name":"datasheetvend_list_component_twins","title":"List your datasheets that have a component twin","description":"List the datasheets in your DatasheetVend account that have a Unified Component Model (UCM) digital twin: the facts DatasheetVend already extracted from each datasheet — pins, supply rails, interfaces, registers and whole-part limits — combined across the extraction runs stored for it. Returns each datasheet's exact name, the modules its twin draws on, how many runs it has and when it was last run","read_only":true},{"name":"datasheetvend_get_component_twin","title":"Read a datasheet's component twin","description":"Read the Unified Component Model (UCM) digital twin of one datasheet already extracted with DatasheetVend. Every fact comes with a check ('passed', 'needs_review', 'disagrees', 'failed_sanity_check') and, where the extraction recorded one, its datasheet page, filed where it belongs: pins, whole_part (temperatures, absolute limits, package, ordering code), interfaces_rails (I2C/SPI/clock/ADC requir","read_only":true},{"name":"datasheetvend_build_component_twin","title":"Extract a datasheet into a component twin","description":"Extract a datasheet with DatasheetVend Fast Extraction and return its Unified Component Model (UCM) digital twin in one call. Fast Extraction runs once for every requested module, and the modules' facts combine into one twin, filed where they belong: pins, whole_part (temperatures, absolute limits, package, ordering code), interfaces_rails, registers and checks — every fact with a check ('passed',","read_only":true}],"server_info":{"name":"datasheetvend","version":"1.0.0"},"category":"web-search","tags":["productivity","legal","design"],"kind":"remote","source":"registry","submitted":{},"first_party":true,"domain_rank":null,"score":100,"indexable":true,"first_seen":"2026-10-27","stars":0,"badges":["new"],"sponsor":null,"page":"https://agentsindex.org/agents/com-datasheetvend-datasheet-contracts/"}