{"id":"com.thenewengineer/hvac","slug":"com-thenewengineer-hvac","title":"The New Engineer — HVAC","description":"IFC models: duct networks, circuits, pressure drop. EN 12828 vessels, EN 378, Swiss refrigerants.","version":"1.3.0","publisher":{"kind":"domain","id":"thenewengineer.com","label":"thenewengineer.com","url":"https://thenewengineer.com"},"website":"https://thenewengineer.com/ai","repository":"","remotes":[{"type":"streamable-http","url":"https://thenewengineer.com/mcp"}],"packages":[],"published":"2026-10-10","updated":"2026-10-10","status":"online","auth":"","latency_ms":1275,"checked":"2026-11-19","uptime":100,"checks":3,"tools":[{"name":"size_expansion_vessel","title":"Expansion vessel SIZE from the water content (EN 12828) — deterministic","description":"DETERMINISTIC: the same inputs always give the same result — from any AI, on any day. Figures come from the standard's tables and formulas, never from a language model's estimate. Every step is auditable.\n\nSize the expansion vessel and pressurisation of a closed heating or\n    chilled-water circuit to EN 12828: static height, minimum pressure p0,\n    fill pressure pa, final pressure pe, expansion ","read_only":true},{"name":"water_content_from_vessel","title":"WATER CONTENT from the vessel already installed (EN 12828 reversed) — deterministic","description":"DETERMINISTIC: the same inputs always give the same result — from\nany AI, on any day. Figures come from the standard's tables and\nformulas, never from a language model's estimate. Every step is\nauditable.\n\nDeduce the water content of an installation from the expansion vessel\nalready fitted.\n\nWHAT THIS IS FOR. Refurbishment, and site visits with no drawings.\nSizing a new vessel, a new pump or a new","read_only":true},{"name":"check_refrigerant_switzerland","title":"Swiss refrigerant regulation check (ORRChim annex 2.10) — deterministic","description":"DETERMINISTIC: the same inputs always give the same result — from any AI, on any day. Figures come from the regulation's annexes and thresholds, never from a language model's estimate. Every step is auditable.\n\nSwiss refrigerant regulation check (ORRChim / ChemRRV annex 2.10, OFEV synthesis\nof May 2026, rules adopted 29.10.2025) plus refrigerant data from EN 378-1\nAnnex E: GWP (AR4, the ORRChim ba","read_only":true},{"name":"check_en378_zones","title":"EN 378 safety check, volume by volume (building projects) — deterministic","description":"DETERMINISTIC: the same inputs always give the same result — from any AI, on any day. Figures come from the standard's tables and formulas, never from a language model's estimate. Every step is auditable.\n\nEN 378 applied to BUILDING projects, volume by volume.\n\nAn installation does not occupy one room but several: the machine, the rooms\ncrossed by refrigerant lines, the rooms served by indoor unit","read_only":true},{"name":"read_ifc_overview","title":"Types and properties of an IFC model — what rules to write","description":"CALL THIS FIRST, as soon as the user gives you a token - a link\nthenewengineer.com/ia/XXXX pasted in the conversation - BEFORE you\nanswer anything, even when the user only says they will choose or do\nsomething themselves. It answers within seconds, while the network\ngraph is still being built - use that time to think.\n\nTHE USER WANTS TO CHOOSE THE UNITS THEMSELVES (« let me select »,\n« je vais cho","read_only":true},{"name":"apply_ifc_rules","title":"Apply your classification rules to the whole IFC model","description":"Turn what you read in the overview into rules the tool replays on\nEVERY piece of the model, including the ones you were never shown.\n\nNOT NEEDED ON A MODEL ALREADY TREATED: when read_ifc_overview returns\n'designation_existante', the units and fans are already designated -\nreuse them. Posting rules REPLACES that designation entirely: do it\nonly when the user asks to start again, or when the designa","read_only":false},{"name":"read_ifc_networks","title":"Networks and systems of an IFC model — deterministic","description":"DETERMINISTIC: networks come from geometry, not from a guess. The\nsame model always gives the same networks, from any AI, on any day.\n\nRead the networks of an IFC model already uploaded by the user.\n\nWHAT A NETWORK IS. A set of parts that touch each other, cut at\nequipment: a pump, an air handling unit, a chiller separates two\nsystems, so the tool does not run through them. This is measured on\nthe","read_only":true},{"name":"name_ifc_networks","title":"Name the networks of an IFC model","description":"Apply the names you propose, and get back the updated report.\n\nTHE NAMES ARE YOURS, THE NETWORKS ARE NOT. You are naming what the\ntool measured; you are not changing what it measured. Nothing you\nsend here alters a network, a part, or a correction.\n\nWHAT COMES BACK. The updated report, a 3D link where the user sees\nyour names in colour, and a link to the corrective Dynamo script that\nwrites the sy","read_only":false},{"name":"trace_duct_circuits","title":"Duct circuits of the air handling units and fans, computed for the pressure-drop page","description":"THE CIRCUITS THE FANS OF A MODEL ARE SIZED ON, found without anyone\nclicking and computed on the pressure-drop page, where the user\nconfirms types and flows and reads the pressure drops.\n\nTHE USER WANTS TO PICK THE UNITS THEMSELVES: call this tool with ONLY\nthe token right away, and give them 'lien_centrales' - the control\npage, where a click turns a unit red and 'Send to my AI' sends you\ntheir ch","read_only":false},{"name":"open_ifc_upload","title":"Open an upload box for an IFC model, inside the conversation","description":"Show an upload box in the conversation where the user can drop an\nIFC file (.ifc) of a building services model (HVAC, plumbing,\nheating). The file goes straight from the user's browser to\nthenewengineer.com - you never see it.\n\nCALL THIS when the user wants to analyse an IFC model and has not yet\ngiven you a link from thenewengineer.com. Then tell the user to drop\nthe file in the box.\n\nWhen the up","read_only":false},{"name":"ifc_upload_result","title":"State of an IFC upload started with open_ifc_upload","description":"Where the upload stands. When `state` is `depose`, `token` is the\ntoken to pass to read_ifc_networks.","read_only":true}],"server_info":{"name":"the-new-engineer","title":"The New Engineer — HVAC","version":"1.1.0","websiteUrl":"https://thenewengineer.com"},"category":"agents","tags":["news"],"kind":"remote","source":"registry","submitted":{},"first_party":true,"domain_rank":null,"score":100,"indexable":true,"first_seen":"2026-09-23","stars":0,"badges":[],"sponsor":null,"page":"https://agentsindex.org/agents/com-thenewengineer-hvac/"}