Agents Index

Ampworth

Online

UK solar PV and heat pump calculators, with guides, on one server. Follows the MCS methods. No key.

Visit publisherConnectJSON

What it can do: 15 tools

  • connection_route read-onlyWork out which ENA connection procedure a domestic installation of solar panels, batteries or both falls under: connect first and notify the distribution network operator within 28 days, or apply and wait for approval be
  • get_document read-onlyFetch the full text of one guide, article or set of questions by its slug, as Markdown, not HTML. Slugs come from search_documents or list_documents. The answer carries the MCS documents the text draws on, and the ids o
  • heat_pump_noise read-onlyCalculate the sound pressure level an air source heat pump produces at an assessment position, and whether it meets the 37 dB(A) permitted development noise limit, using the method in MCS 020. The formula is Lp = Lw + 1
  • heat_pump_running_cost read-onlyCompare what a household spends heating on its current fuel with what the same heat would cost from a heat pump. The heat demand is worked out from the household's own metered fuel use, not from a model, because a year
  • heat_pump_size read-onlyEstimate the heat pump a UK house needs, and what it would cost to run against the fuel it burns now. IMPORTANT: MIS 3005-D requires a heat pump to be sized from a room-by-room heat loss calculation to BS EN 12831, and
  • hot_water_cylinder read-onlyWork out the daily hot water demand of a dwelling and the size of cylinder a heat pump needs, using the formula in MIS 3005-D 3.5.2 and the BS 6700 guidance reproduced in MGD 007. The demand is 45 litres a day for each
  • list_calculators read-onlyLists every calculator on this server, with the standard behind it and whether it is the whole-system sizing calculator or one of the single-method ones, plus the reference data a caller needs to build a valid request: t
  • list_documents read-onlyLists every document, optionally filtered by kind ('guide', 'article' or 'faq'), by category, or, for guides, by the reader they are written for. Guides are shelved by perspective: 'considering', 'buying', 'selling', 'in
  • radiator_flow_temperature read-onlyWork out the flow temperature a heat pump must produce to heat a room through a given radiator, and the resulting MCS Heat Emitter Guide star rating, following section 4 of MGD 007. This is the calculation that decides
  • room_heat_loss read-onlyCalculate the design heat loss of a single room in watts, following BS EN 12831 as MIS 3005-D applies it. This is the figure a heat pump is sized from and the figure the radiator in that room must be able to deliver. BS
  • search_documents read-onlySearch the guides, articles and questions for material on a UK home energy subject. Use this first, before answering from memory, whenever a question concerns UK heat pump or solar PV practice: how a system is sized, wh
  • solar_pv_output read-onlyEstimate the annual AC electricity output of a UK solar photovoltaic system, in kWh, using the standard estimation method that MIS 3002 requires every MCS certified installer to use. The method is: annual output = kWp x
  • solar_pv_self_consumption read-onlyEstimate what proportion of a domestic solar PV system's annual output is consumed in the house and what proportion is exported, using the lookup tables in MGD 003. The tables are not a model. They come from half-hourly
  • solar_pv_shading read-onlyConvert a completed MCS sunpath shading assessment into a shade factor, using the procedure in MGD 005. The MCS sunpath chart is divided into 84 segments, each worth one per cent of the year's useful irradiance. An asse
  • solar_pv_system_size read-onlyWork out the solar PV system a UK home needs: the capacity in kWp, the number of panels, the battery to go with it, and what it would do to the electricity bill. This runs the MCS arithmetic backwards. The other solar c

Connect it

Claude Code
claude mcp add --transport http ampworth https://ampworth.com/mcp
Claude.ai / ChatGPT
Settings → Connectors → Add custom connector
URL: https://ampworth.com/mcp
Cursor (~/.cursor/mcp.json)
{
  "mcpServers": {
    "ampworth": {
      "url": "https://ampworth.com/mcp"
    }
  }
}
VS Code (.vscode/mcp.json)
{
  "servers": {
    "ampworth": {
      "type": "http",
      "url": "https://ampworth.com/mcp"
    }
  }
}

Questions

What does Ampworth do?

UK solar PV and heat pump calculators, with guides, on one server. Follows the MCS methods. No key. It exposes 15 tools to AI assistants.

What tools does Ampworth provide?

15 tools, including connection_route, get_document, heat_pump_noise, heat_pump_running_cost, heat_pump_size, hot_water_cylinder, list_calculators, list_documents, radiator_flow_temperature, room_heat_loss, search_documents, solar_pv_output….

How do I connect Ampworth to Claude, ChatGPT or Cursor?

Add the remote MCP endpoint https://ampworth.com/mcp as a custom connector or MCP server. Copy-paste setup is on this page.

Does Ampworth require an account or API key?

No sign-in was needed to list its tools. Individual tools may still need an account or API key.

Is Ampworth online?

As of 2026-11-19 our probe found it online. It answered 100% of our last 3 checks.

Who publishes Ampworth?

ampworth.com. The official MCP Registry verified that the publisher controls this domain before accepting the listing.

Similar in Productivity & Docs